Using the no-op true command on other paths to that disk, will cause GEOM to re-”taste” the disk and see the label and automatically add the additional paths to the existing multipath. This will write a GEOM Multipath label to the last sector of the disk. Each SAS Expander will present as a new /dev/ses# device, so your system may have more than one.
For chassis with larger numbers of drives, or when connecting external JBOD chassis, it is common for the drives to connect to a specialized board that provides power and routing for the SATA/SAS signals to the controller. When building a storage system, there are many different ways the disks might be connected to the system. NVME-oF allows storage devices and arrays in remote chassis to be connected to local motherboards. NVMe storage comes in many form factors, from small M.2 devices to U.2 and other hot-swappable formats intended for servers. NVMe connects storage devices directly to the PCIe bus, offering extremely low latency and high throughput.
Unfortunately, APM settings don’t persist between power cycles so if we wanted to change disk settings with APM they would need to be reapplied on every boot. Advanced power management levels80h and higher do not permit the device to spin down to save power. For example, a device may implement one power management method from 80h to A0h and a higherperformance, higher power consumption method from level A1h to FEh. To prevent parking more often that is useful (for a server, usually that choice would be “very rarely”), there are a couple ways to do it and which apply will depend on what the hard drive vendor’s firmware supports. With the SMART metrics captured by Prometheus, it’s fairly easy to write a query that will show how often a given disk is parking its heads. Since I use Prometheus to capture information on the server’s operation however, I can use that to monitor that my hard drives are doing well.
SAS disk reservations provide the ability to connect to the disk redundantly—or even across multiple machines—while ensuring it is only used by one of them at a time. SAS provides many more features than SATA does—including full duplex operations, advanced error recovery, multipath, and disk reservations. It too was an extension on an existing interface bus which offered greatly improved performance. SATA+AHCI improved data transfer speeds, simplicity of communication, and included abilities that we today take for granted, such as “hot swap” and command queueing. These concepts also apply to other operating systems, but the tools might differ slightly.

OpenZFS Development & Support

SATA disks plugged directly into the motherboard use an interface called AHCI which does not provide much in the way of advanced management features. For smaller numbers of drives, and for most home systems, the most common way the disks are attached is to the SATA controllers built into the motherboard. Non-Volatile Memory Express (NVMe) is a newer storage interface that is becoming very popular for flash storage devices. Just download the executable file on both devices and run it to open the tool. At a glance, changing idle3 and EPC settings seems to have done the job nicely; here is the same graph of head park rates per disk as before, but on a smaller timescale that makes individual head parks visible. Seagate provide a “Seachest” collection of tools for manipulating their drives, but rather more usefully to users of non-Windows operating systems like Linux they also offer an open-source openSeaChest.

  • Send it to the other user who has the program and they will be able to access and control your device.
  • It’s a datacenter drive, very loud, so it’s still audible.
  • The current settings for a disk can be queried with the –showEPCSettings flag.
  • In this case, there are at least two disks that I probably need to configure, since /dev/sde seems to be parking as often as about every 4 minutes (0.004 Hz) and /dev/sdc is only parking slightly less often.
  • SAS provides many more features than SATA does—including full duplex operations, advanced error recovery, multipath, and disk reservations.
  • I don’t move any data, no apps are running, this is a vanilla Scale install so far, yet the HDD is in constant work.

sesutil locate

Other interfaces for remote storage include iSCSI, Fiber-Channel, Infiniband, RoCE, and others, but those specialized solutions are beyond the scope of this article. Serial Attached SCSI (SAS) is the most common interface for enterprise storage, first appearing in 2004. Serial ATA (SATA) is the familiar interface used for non-enterprise storage, and is an extension of the original ATA interface dating from the 1980s. In this article we will discuss some strategies and tools to make managing disk arrays on FreeBSD (and related platforms like TrueNAS Core) much easier. It may be what you want is to enable HDD standby, which will “spin down” the drives when not in use

Unlock the Power of OpenZFS, Linux, and FreeBSD with Klara’s Open Source Development Experts

If you need more advanced functionality than mpsutil provides, LSI provides their native tools sas2ircu and sas3ircu for FreeBSD. On my system, this command produces a bright red LED lit for that slot, physically highlighting the correct drive to replace. So, to activate the LED for the first disk displayed above, we first need to determine the enclosure handle number (0001), and then the slot number of the disk (03). This partitions each disk and labels the ZFS partition with the enclosure, slot, and serial number of the corresponding disk. As with a number of tools in FreeBSD, sesutil supports outputting JSON via the libxo library.

Embedded ARM Development Experts

Sounds like the drives being woken for the ZIL to flush writes to the ZFS pool and then going back to idle/sleep every 5 seconds. Enable the checkmark for the Syslog and choose a pool that is not based on hard drives. I had this same problem, using HGST data center refurb drives.
Once you’ve done so, you must test delivery to your “real” inbox—you don’t want to learn that delivery isn’t working after your storage has already become unavailable! If you’d feel safer with a team of experts monitoring your storage, consider a ZFS Support Subscription. If you rely on manually checking on your storage periodically, you will regret it. Another important aspect of managing your storage system is configuring notifications. Klara recommends embedding these details directly into the ZFS vdev properties of each disk—a feature Klara created, which will become generally available in the upcoming OpenZFS 2.2 release. In these configurations, your system may or may not support features like individual “locate” and “fault” LEDs.

The parking rate basically drops to zero at the time I updated the settings for the Seagate drives, and the Western Digital one hasn’t changed because it needs to be powered off to change that setting and I haven’t done so yet. The other slight annoyance when setting the idle3 timer on WD drives is that changes only take effect when the drive is powered on, usually meaning the host computer must be fully shut down and started back up for any changes to be seen- this makes experimentation to determine how raw timer values are interpreted a slower and more tedious process. Of particular note, WD Green drives ship configured to park the heads after only 8 seconds of inactivity which could notionally wear out the disk in a matter of months if the heads are cycling more-or-less continuously! For drives made by Western Digital, the inactivity timer for parking the heads is called the idle3 timer.

  • It’s self-hosted and self-managed, so data remains within your company network.Bank-Level EncryptionBanking-standard TLS 1.2 technology protects your computer from unauthorized access.
  • These communities are filled with knowledgeable individuals who can offer more personalized advice and help you navigate the complexities of long-term data storage.
  • We can also see that the disk in Slot07 was recently swapped, and that Slot08 does not contain a disk and its locate LED is activated.
  • Advanced power management levels80h and higher do not permit the device to spin down to save power.
  • With decades of experience in IT management and later as a writer and tutor, she combines technical knowledge with a passion for clear communication.
  • This has long been the interface bus used by most home users to connect their hard drives, and is supported by nearly every motherboard.

I set power mode to Idle and advanced power management to the lowest setting (1) which should spin down the disk after 5 mins. Hello,Like many users of Seagate Exos drives, I have found that they park their heads very aggressively, approximately every 2 minutes. AnyDesk allows you to establish remote desktop connections between devices and opens up unprecedented possibilities of collaborating online and administrating your IT network. Its primary purpose is to grant bidirectional remote access between personal computers and mobile devices. To do this, both devices must have the program installed and must allow access through the use of security keys. The current settings for a disk can be queried with the –showEPCSettings flag.
For ZFS users, automating fault responses with tools like ZED (ZFS Event Daemon) can simplify disk replacement and minimize downtime. Configuring your system to notify you when a disk has errors, or when the filesystem reports a degraded device, will ensure your system gets prompt attention when something goes wrong. Experienced enterprise storage managers also keep extensive notes including the model number, SKU and/or URL for reordering, purchase order information, warranty end date, warranty URL, and any other useful information about each drive. While the operating system typically provides device aliases based on the disk’s serial number, WWN, or some other static identifier, this does not provide all of the information you might want.
However, I noticed that my HDD’s heads park (particulary Seagate Exos) every 3 minutes. ZFS is widely trusted for large-scale storage, but production environments expose design mistakes,… When dealing with critical data, you only get one chance to do it right. The status field is a bitmask supporting a number of different options, but the main ones we care about are 1 (OK), and 2 (FAULTED). When combined with a JSON parser like jq, this can be used to automate tasks for each disk.
I noticed that even when doing nothing, I hear the sound of drives working every few seconds. I gave up and just built a Windows Storage Space with tiering and the drives are now effectively silent. I guess it depends on the drives, but don’t think you’ll find any software solution. My Seagate Exos enterprise drives make almost 0 noise actually. The system is never idle really, it’s a server. What causes the constant load on the disk?

Can I setup automatic connection without a password on AnyDesk?

It is fairly well-known among techies that hard drives used in server-like workloads can suffer from poor configuration by default such that they frequently load and unload their heads, which can cause disks to fail much faster than they otherwise would. My Seagate Archive SMR disk (which began life as an external hard drive and was retired from that role when it became too small to hold as much as I wanted to back up to it) apparently doesn’t support reporting EPC settings (since asking for them says so), and initially didn’t accept new values for the idle timers either. The Prometheus Node Exporter is the canonical tool for capturing machine metrics like utilization and hardware information with Prometheus, but it alone does not support probing SMART data from storage drives. While SSDs don’t have any heads to park, most do report a media_wearout_indicator that represents the amount of data written to the device in relation to the amount that it’s specified to accept before the Flash storage medium wears out.
The timer values specified are in milliseconds, so this example will park the disk heads after 30 minutes of inactivity. If we wanted to allow the disk to still park its heads but at minimum frequency, setting the APM value to 7Fh (hdparm -B 127) seems to be the correct choice. Of the three disks that I decided need some attention, I have one Western Digital disk and reveryplay two Seagate ones.